Automatic Chlorine Feeder -> PERFORMANCE FEEDER - SSP TYPE Easily and Simple Operations with high safety performance.
Characteristics: Easily Controlled By Advanced Technology
- A combination of a weekly timer and a chemical timer controls the feed amount of the chemical at will
- Frameless system realises easy maintenance
- Transparent chemical hopper has a capacity of 15 kg.
- Standard equipment includes interlock, enabling linked operation with the filter pump
- Residual Chlorine meter can be connected by using a one-touch coupler (option)
- 200V. specification device available
Specifications of the Device
|
425 mm. x 986 mm. x 670 mm. |
|
100V single phase / 200V single phase |
|
2.5A/100V, 2.0A/200V at 60Hz 2.0A/100V, 1.5A/200V at 50Hz |
|
Polarography method, bead wash type, three electrode system (option) |
|
17 kg for 100V device / 18 kg for 200V device |
|
Nissan DCCNa-60 |
Chemical hopper capacity:
|
max. 15 kg |
|
ca . 30 g/once |
Dissolution tank capacity:
|
25 L effective |
|
one graduation represents 2 hours, 24-h setting/1 week type |
|
free setting (min. 2 min) |
|
equipped as standard |
|
max. 1500 m3 |
|
|
Standard Amount of Use:
When operated 12 hours a day at a free residual chlorine concentration of 0.4 - 1.0 mg./L.
|
Amount of Water |
Setting of the Chemical Timer |
Amount Chlorine Preparations Use Per Day |
50t |
Not less than 60 min |
ca. 360 g. |
100t |
35 - 40 min |
ca. 600 g. |
200t |
30 - 35 min |
ca. 720 g. |
300t |
25 - 30 min |
ca. 840 g. |
400t |
20 - 25 min |
ca. 1,080 g. |
500t |
15 - 20 min |
ca. 1,440 g. |
600t |
10 - 15 min |
ca. 2,160 g. |
1200t |
5 - 10 min |
ca. 4,320 g. |
|
| * As the free residual chlorine concentration will change drastically depending on the weather and the number of people swimming, please set the timer accordingly. |
|
|